NoTap™ Tigerholm® Series

8 October 2019

Quick and easy

[cy_video id=”w1rZULMugzw”]

[cy_video id=”9tQfGeHjtts”]

[cy_video id=”bkuUSRz9JNM”]

[cy_video id=”Nhm3WcSVvnk”]

10 good reasons to use NoTap™

  1. No necessity to drain a building or pipework system.
  2. No refilling with water and air venting system, radiators or equipment after completion of works.
  3. Ease of installation without threading, grooving, welding, brazing or soldering.
  4. Suitable for Steel Barrel-black & galvanised, Stainless steel, copper and Carbon steel tubes.
  5. Energy efficient. No heated water needs to be drained from the system or any re-introduced cold water needs to be heated.
  6. No Hot work Hazard demanding stringent fire precautions.
  7. Reduced system corrosion as no oxygen rich water is introduced into the system.
  8. Environmentally friendly as no hazardous water requires to be drained. No loss of expensive water treatment chemicals.
  9. No debris or fragments from drilling enter the system.
  10. Economic, speedy and efficient pipe modifications and Repairs.

Cost effective

Advantages for the contractor

  • The job time is reduced considerably
  • Better profitability as more jobs can be carried out within a given time period
  • Solves problems that are otherwise difficult to manage
  • Can offer customers better service and solutions
  • No need to handle chemicals when modifying cooling systems

Advantages for the property owner

  • Tenants are not disturbed during pipe work
  • Tradesmen in the building are able to carry on their operation despite the pipe work (dentists, hospitals, airports, etc.)
  • Lower installation costs
  • Work can be carried out during normal business hours eliminating the need for costly weekend or after hour work
  • Less corrosion in the water system for increased life expectancy of the system
  • Reduced risk for water damages due to faucets left open
  • Environmentally friendly

Mobile demonstration unit

We have now introduced a mobile demonstration team to provide comprehensive practical experience and training of both NoTap™ ballooning and branching at our premises, your workshops and even worksites. We emphasise the demonstrations are part of our program to reinforce the confidence of operatives in using NoTap equipment and products

The demonstrations are without cost to yourselves and can contribute to the continuing professional development of your staff. They display how significant results are achieved with complete ease. The demonstations reveal the enormous potential NoTap™ kits have in cutting costs, saving energy and reducing downtime when modifying and repairing pressurised pipe installations. Should you wish to take advantage of our offer to see the team in action please contact us at the earliest opportunity to arrange the date, time and place.

Branch connection in 4 simple steps

NoTap Technical diagram

Technical data

Max system pressure: 16bar (10 bar on pipe dims. above DN 150)
Max temp: 95° C (105° C on branch outlets DN40 and larger)
Min temp: -10° C

1. Mount NoTap™ clamp

1. Mount NoTap™ clamp

2. Install full-flow ball valve

2. Install full-flow ball valve

3. Drilling with NoTap

3. Drilling with NoTap

4. Making branch connection

4. Making branch connection

Technical ingenuity

Drilling hole to ensure proper flow

Drilling hole to ensure proper flow

The first step in making your branch connection with NoTap™ is to choose a clamp with the desired size outlet. Clamps are available for pipes from 26 – 335 mm OD. The outlet size varies depending on pipe size. Outlets available are 1″, 11/2″, 2″ and 2 1/2″.

The NoTap™ method combines a centre drill bit with a hole saw. Once the centre drill bit penetrates the pipe, a flow will start to run through the tooling and out through the flushing device. This will ensure that chips and pipe shavings are carried away from the flow inside the pipe.
Drilling hole to ensure proper flow - image 2

Next, the hole saw will start to cut through the pipe. The hole saw will cut through the pipe and also other layers of deposits that might be coated to the inside of the pipe. Using a hole saw will ensure that a proper hole is opened in the pipe for desired flow. The threaded centre drill bit drills itself into the portion of pipe that is cut out. This way the cut out portion of pipe is always retained (not lost in the pipe system).
Drilling hole to ensure proper flow - image 3

Drilling hole to ensure proper flow - image 4

When the hole saw has penetrated the pipe, simply retract (pull back) the drill until it stops. Then close the ball valve as shown in the picture. Finally, unscrew the drill housing from the ball valve and make the necessary branch connection.

When the job is finished, it is always a good idea to disassemble the NoTap™ tooling and dry it off for future use.

Tiger Connect toolkit

For branch connections on pipes with OD 26 mm to 335 mm

Tiger Connect toolkit

The Tiger Connect toolkit contains complete equipment for making branch connections on pipes with outer diameter OD 26 – 335 mm. Branch connections can be made with outlets of 1″, 1 1/2″, 2″ and 2 1/2″.

Refer to next tab for dimension tables.

Clamps give flexibility

NoTap™ clamps can be used on all types of steel

NoTap Clamps can be used on all types of steel

K1 clamps are manufactured in brass, which means the same clamp can be installed on stainless steel, galvanised steel, mild steel, painted steel and even copper. The clamps can also be used on certain types of PVC plastic (ask the factory for more info.). Even NoTap™ big clamps can be used on these same materials due to the rubber seal, which acts as a barrier between the pipe and the clamp.

Odd pipe sizes? No problem with NoTap™!

Odd pipe size? No problem with NoTap!

NoTap™ is very often used for renovating or building onto to existing pipe systems. Many older pipes have odd pipe diameter dimensions. This is not a problem for NoTap as our unique clamp design allows each clamp to cover a dimension range.

K1 Clamps for 1” ball valve outlet

K1 Clamps
K1 clamps 2

K1 Clamps sold without ball valves

Suitable for pipes with outside diameter from 29mm to 170mm.

Article No.Pipe diameter OD min/maxMain dimensionBranch outlet
1403028E-0226-32DN20Cu 28DN25
1403035E-0233-38DN25/Cu 35DN25
1403042E-0239-45DN32/Cu 42DN25
1403048E-0246-51DN40DN25
1404054E-0550-58Cu54DN25
1404060E-0555-65DN50DN25
1404068E-0561-75Cu 70DN25
1404076E-0574-83DN65/Cu 76,1DN25
1404083E-0577-8877-88DN25
1404089E-0585-98DN80/Cu 88,9DN25
1404102E-0594-111Cu100DN25
1404114E-05108-125DN100/Cu 108DN25
1404129E-05122-138Cu 133DN25
1404140E-05136-152DN125DN25
1404152E-05145-160Cu 159DN25
1404168E-05158-170DN150DN25

NoTap Big Clamps for 1 1/2” ball valve

NoTap Big Clamps for 1 1/2 inch ball valave outlet
NoTap Big Clamps for 1 1/2 inch ball valave outlet 2

NoTap™ Big Clamps sold with ball valves

Suitable for pipes with outside diameter from 54mm to 165mm.

Article No.Pipe diameter OD min/maxMain dimensionBranch outlet
146054E-0154-58Cu 54DN40
146060E-0160-67DN50DN40
146063E-0163-70Cu 70DN40
146065E-0175-82DN65/Cu 76,1DN40
146070E-0182-89DN80/Cu 88,9DN40
146080E-0188-95DN80/Cu88,9DN40
146099E-01112-135DN100DN40
146130E-01145-165Cu 159DN40

NoTap big Clamps for 2” ball valve outlet

NoTap Big Clamp for 2in ball valve outlet
NoTap Big Clamp for 2in ball valve outlet - Image 2

NoTap™ Big Clamps sold with ball valves

Suitable for pipes with outside diameter from 70mm to 134mm.

Article No.Pipe diameter OD min/maxMain dimensionBranch outlet
146064E-0170-77Cu 70DN50
146066E-0175-82DN65/Cu 76,1DN50
146071E-0182-89DN80/Cu 88,9DN50
146081E-0188-95DN80/Cu 88,9DN50
146085E-0195-102Cu 100DN50
146090E-01102-112Cu 108DN50
146100E-01112-134DN100DN50

NoTap™ Big Clamps for 2 1/2” ball valve outlet

NoTap Big Clamp for 2 1/2in ball valve outlet
NoTap Big Clamp for 2 1/2in ball valve outlet - Image 2

NoTap™ Big Clamps sold with ball valves

Suitable for pipes with outside diameter from 88mm to 335mm.

Article No.Pipe diameter OD min/maxMain dimensionBranch outlet
146082E-0188-95DN80/Cu 88,9DN65
146086E-0195-102Cu 100DN65
146091E-01102-112Cu 108DN65
146101E-01112-134DN100DN65
146125E-01133-155DN125/Cu 133DN65
146132E-01145-165Cu 159DN65
146150E-018168-188DN150DN65
146170E-01190-210204DN65
146200E-01215-235DN200DN65
147225E-01251-271251/271DN65
146250E-01272-292DN250DN65
146270E-018292-315292/315DN65
146300E-01315-335DN300DN65